about us     SPECIFICATIONS &
TECHNICAL DATA
    Guardrail Products     contact us  
 
 

 

  1. Base Metal specification to AASHTO M180.89
    Minimum Yied Strength: 345 N/mm2
    Minimum Tensile Strength: 490 N/mm2
    Minimum Elongation: 15%

  2. Galvanising specification to AASHTO M180.89
    1100g/m2 minimum single spot test
    1220g/m2 triple spot test

  3. PRESTAR dimension to AASHTO - M180.89


Prestar Guardrail & Post Specifications

GUARDRAIL

Type Effective
Length (mm)
Overall Length (mm) Nominal Uncoated Thickness (mm) Weight (kg)
PE 1 3810 4128 2.67 44.0
PE 2 4000 4318 2.67 46.0
PE 3 3810 4128 3.00 48.0
PE 4 4000 4318 3.00 50.0


Click for larger picture
   
   


PRESTAR POST

Type H x B x t2 x T1 (mm) Unit Weight (kg.m) Section Area (cm2) Moment Of Inertia Section Modulus
lx (cm4) ly (cm4)

Sx(cm3) Sy (cm2)
A C178 x 76 x 6 x 6 14.3 19.08 903.5 102.5 101.5 52.0
B C125 x 65 x 6 x 8 13.4 17.11 425 65.5 68.0 14.4


 


 
     
<< Back to Listing
 